FTIR spectroscopy of 2-0 band of carbon monoxide confined in silica aerogels with different pore sizes /A. A. Solodov, T. M. Petrova, Yu. N. Ponomarev [et al.]

Электронный ресурс
Другой Автор
Petrova, Tatiana M.
Ponomarev, Yuriy N.
Solodov, Alexander M.
Danilyuk, A. F.
Solodov, Alexander A.
Источник
Molecular physics 2019 Vol. 117, № 1. P. 67-70
Аннотация
The absorption spectra of carbon monoxide confined in three aerogel samples with different pore sizes have been recorded within the 4100–4400 cm-1 spectral region at room temperature. The measurements were made using a Bruker IFS 125HR Fourier-transform infrared spectrometer. Lineshift and half-width values for CO were obtained. The influence of pore sizes on dependence of CO line half-width values on rotational quantum numbers was studied.
Всего оценка: 0
Нет записей для отображения.
 
 
 
01820nab a2200349 c 4500
001
 
 
vtls000660099
003
 
 
RU-ToGU
005
 
 
20190708164400.0
007
 
 
cr |
008
 
 
190704|2019    enk     s         a eng dd
024
7
$a 10.1080/00268976.2018.1495846 $2 doi
035
$a to000660099
039
9
$a 201907081644 $b cat34 $c 201907081628 $d cat34 $c 201907041630 $d VLOAD $y 201907041620 $z VLOAD
040
$a RU-ToGU $b rus $c RU-ToGU
245
1
0
$a FTIR spectroscopy of 2-0 band of carbon monoxide confined in silica aerogels with different pore sizes $c A. A. Solodov, T. M. Petrova, Yu. N. Ponomarev [et al.]
504
$a Библиогр.: 15 назв.
520
3
$a The absorption spectra of carbon monoxide confined in three aerogel samples with different pore sizes have been recorded within the 4100–4400 cm-1 spectral region at room temperature. The measurements were made using a Bruker IFS 125HR Fourier-transform infrared spectrometer. Lineshift and half-width values for CO were obtained. The influence of pore sizes on dependence of CO line half-width values on rotational quantum numbers was studied.
653
$a Фурье-спектроскопия
653
$a монооксид углерода
653
$a аэрогели
655
4
$a статьи в журналах
700
1
$a Petrova, Tatiana M.
700
1
$a Ponomarev, Yuriy N.
700
1
$a Solodov, Alexander M.
700
1
$a Danilyuk, A. F.
700
1
$a Solodov, Alexander A.
773
0
$t Molecular physics $d 2019 $g Vol. 117, № 1. P. 67-70 $x 0026-8976
852
4
$a RU-ToGU
856
4
$u http://vital.lib.tsu.ru/vital/access/manager/Repository/vtls:000660099
908
$a статья
999
$a VIRTUA
999
$a VTLSSORT0070*0080*0240*0350*0400*2450*5040*5200*6530*6531*6532*6550*7004*7000*7001*7002*7003*7730*8520*8560*9080*9992
Нет комментариев.
Предмет
статьи в журналах
Резюме
The absorption spectra of carbon monoxide confined in three aerogel samples with different pore sizes have been recorded within the 4100–4400 cm-1 spectral region at room temperature. The measurements were made using a Bruker IFS 125HR Fourier-transform infrared spectrometer. Lineshift and half-width values for CO were obtained. The influence of pore sizes on dependence of CO line half-width values on rotational quantum numbers was studied.